Thermocouple Cables | |||
Flat Single Pair High Temp. Glass Insulated
Application
These cables are used with thermocouples for temperature measurements.
Specification
Conductor: Solid. Material is according to thermocouple type.
Insulation: High Temp. glass
Outer sheath: High Temp. glass
Construction: Flat
Color code: According to IEC 60584-3
K Type
AWG(mm) |
Insulation Material |
Sheath Material |
Max. Temp. (°C) |
Nominal O.D. (mm) |
Weight (kg/km) |
24 (0.51) |
High Temp. Glass |
High Temp. Glass |
704 |
1.4 x 2.3 |
10.0 |
20 (0.81) |
High Temp. Glass |
High Temp. Glass |
704 |
1.5 x 2.7 |
13.4 |
E Type
AWG(mm) |
Insulation Material |
Sheath Material |
Max. Temp. (°C) |
Nominal O.D. (mm) |
Weight (kg/km) |
24 (0.51) |
High Temp. Glass |
High Temp. Glass |
704 |
1.4 x 2.3 |
10.0 |
20 (0.81) |
High Temp. Glass |
High Temp. Glass |
704 |
1.5 x 2.7 |
13.4 |
J Type
AWG(mm) |
Insulation Material |
Sheath Material |
Max. Temp. (°C) |
Nominal O.D. (mm) |
Weight (kg/km) |
24 (0.51) |
High Temp. Glass |
High Temp. Glass |
370 |
1.1 x 2.2 |
10.0 |
20 (0.81) |
High Temp. Glass |
High Temp. Glass |
480 |
1.5 x 2.7 |
13.4 |
N Type
AWG(mm) |
Insulation Material |
Sheath Material |
Max. Temp. (°C) |
Nominal O.D. (mm) |
Weight (kg/km) |
24 (0.51) |
High Temp. Glass |
High Temp. Glass |
704 |
1.4 x 2.3 |
3.4 |
20 (0.81) |
High Temp. Glass |
High Temp. Glass |
704 |
1.5 x 2.7 |
6.7 |